o Compra Osciloscopio Automotriz Usb Inyeccion Electronica Encendido en Capital Federal por $ 450000

Osciloscopio Automotriz Usb Inyeccion Electronica Encendido

Ubicacion: Villa Crespo, Capital Federal
Disponibilidad: en stock en stock
Estado: Nuevo

En Oferta:
$ 450.000
Esta Oferta Termina en:

Apurate ! Quedan solo productos en stock !

Anuncios Clasificados

Osciloscopio Hantek1008c

ESPECIFICACIONES

- 8 canales de prueba, 12 bits de resolución vertical
- Con generador programable de 8 canales
(genera secuencias programables de señal cuadrada)
- Trabaja en: Windows NT, Windows 2000, Windows XP, VISTA, Windows 7, Windows 10
- Velocidad de adquisision 2.4 millones de muestras por segundo en tiempo real
- Prueba de voltaje 10mv/ divi a 5 V/ div
- Visualización max +/- 15V
- Con atenuador 20:1 (No incluido) +/- 300V

Característica
Altamente eficiente y rentable; 8 canales de osciloscopio para la inspección de vehículos; 2.4MSa / s frecuencia de muestreo en tiempo real, resolución vertical de 12 bits; función de la tarjeta de adquisición de datos; 8 canales generador programable que puede analógico señales de cigüeñal , árbol de levas, etc
1) Osciloscopio,
* 8 canales de osciloscopio, 2.4MSa / s frecuencia de muestreo en tiempo real
* 12 bits de resolución vertical, función de análisis de espectro
3) programable Generator2
*8 canales del generador programable
* Puede analógico señales de cigüeñal, árbol de levas, etc
4) Otros
* Enchufe del USB 2.0 de interfaz y el juego, y no necesita fuente de alimentación adicional;
* Más de 20 tipos de función de prueba automática, una interfaz similar con el osciloscopio de sobremesa, fácil de usar ;
* El soporte de software: Windows NT, Windows 2000, Windows XP, Vista, Windows 7, Windows 8, Windows 10

Modelo Hantek1008 2019
Modo Osciloscopio
Sistema Vertical
Canal Analógico 8
Impedancia de entrada Resistencia: 1MO
Sensibilidad de entrada 10mV/div a 5V/div
Acoplamiento de entrada Corriente continua
Resolución 12 bits
Sistema Horizontal
Profundidad de la memoria 4K
Max. Entrada 400V (DC + AC pico)
Real-Time Sampling Rate 2.4MSa / s
Tiempo BaseRange 1ns/div a 20000s/div (1-2-5sequences)
Base de tiempo de precisión 50 ppm ±
Sistema de disparo
Gama de base 1ns/div a 20000s/div (1-2-5sequences)
Base de tiempo de precisión 50 ppm ±
Fuente del disparador CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8
Modo de disparo Borde
Modo XY
Eje X Input CH1
Eje de entrada CH2
Los cursores y Medición
Medición de voltaje Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vmed, Vrms, Vcrms, Preshoot, Overshoot
Medición del tiempo Frecuencia, Periodo, Tiempo de subida, Tiempo de bajada, anchura positiva, anchura negativa, ciclo de trabajo
Los cursores de medida Horizontal, Vertical, Pista, Modos Auto Medición
Proceso de la forma de onda de la señal +, -, X, ÷, FFT, Invert
Rango de voltaje
10mV a 5V/div @ x 1 sonda de
100 mV a 50V/div @ x 10 sonda de
10V a 5000V/div @ x 1.000 sonda
100V a 50000V/div @ x 10000 sonda
200mV a 100V/div @ 20:01
Gama de corriente 100mA to50.0A/div @ CC65 (20A)
1000mA to500.0A/div @ CC65 (65A)
1A to100.0A/div @ CC650 (60A)
1A to200.0A/div @ CC1100 (100A)
10A to2000.0A/div @ CC1100 (1100A)
FFT Rectangular, Hanning, Hamming, Blackman ventana
Matemáticas Suma, resta, multiplicación, división
Generador Programable
Canal 8
Nivel de salida LVTTL
Rango de frecuencia 0-250kHz
Interfaz USB 2.0
Potencia No necesita fuente de alimentación adicional
Tamaño y Peso 185 x 150 x 27 (mm); 0,35 kg

Function Selection
There are three functions of vehicle diagnosis, osciloscope and signal generator, including 78 types of vehicle diagnosis function.

One Button Screenshot
Save the current waveform and generate pictures. Storage location is optional and easy to find.

Quick Guide
Callout the quick guide column with one button. There are special vedio guide for each vehicle diagnosis function, including wiring method, adjustment method, reference waveform etc. And it is supported to be checked through scanning the QR code.

Reference Waveform
There are 78 types of standard reference waveform inside and can be callout or close with one button. It is convenient to be compared.

Measurement Method
20 types of automatic measurement method which can be callout or close with one button. It is convenient and visual to read out the result.

Print
The result can be printed with one button and generate diagnosis report which is easy to be saved and recorded.

REF Comparison Waveform
The user can save the waveform as REF format and callout it again when you need to compare the two waveforms catched in different time.

Data Storage
The diagnosis result can be saved as the format of txt, csv, rfc, xls, doc, jpg and etc. It is convenient to be checked and compared later.

8CH Vehicle Diagnosis
8CH signal can be measured simultaneously. The measurement voltage of each channel can be adjusted independently. You can choose to open or close each channel.

Waveform Record
Support to record and replay the waveform. The waveform can be save into the computer hard disk and easy to read. There is no limit to the record time which can long-time measure and record the waveform for troubleshooting.

Multilanguage Support
Support the display surface in Chinese, English, German language, and it can be switched freely.

Cursor Measurement
Support 4 types of cursor measurement mode -cross,track, horizontal, and vertical.It's easy to read out the time and voltage of irregular signal.

Color and Lightness
The background color is optional as user's preference. And the lightness of waveform and gridding is settable.

Easy to Install Software
Install the PC software and start to use without any other drivers. Support WIN XP/7/8/10.

USB Communication
USB2.0 power supply + communication interface, plug and play, and support hot plugging.

Signal Generator
Signal generator function, can simulate crankshaft and camshaft signal.

Vehicle Diagnostic Function

Primary Ignition (Voltage)
Primary Ignition (Current)
Primary Ignition (Voltage & Current)
Primary Ignition (Crankshaft Senser)
Primary Ignition&SecondaryIgnition
Secondary Ignition Distributor (Plug Lead)
Secondary Ignition Distributor (King Lead)
Secondary DIS (Positive-fired)
Secondary DIS or CPC (Negative-fired))
Secondary Coil Output Diagnosis
Secondary Ignition&Primary Ignition

Sensors

Air Flow Meter (Hot Wire)
Air Flow Meter (Air Vane)
Air FlowSensor (BOSCH Diesel)
Air Intake PressureSensor (BOSCH Diesel)
Camshaft (Inductive)
Camshaft (AC Excited)
Camshaft (Hall Effect)
Camshaft (BOSCH Common Rail Diesel)
Crankshaft Inductive Running
Crankshaft Inductive Cranking
Crankshaft Hall Effect
Crankshaft Sensor &Primary Ignition
Distributor Pick-up (Hall Effect)
Distributor Inductive Pick-up Cranking
Distributor Inductive Pick-up Running
Lambda Sensor Titania
Lambda Sensor Zirconia
Lambda Sensor Zirconia Pre & Post cat
Throttle Position Potentiometer
Throttle Position Switch
Throttle Pedal Switch (Bosch Diesel)
ABS Digital Speed Sensor
ABS Analog Speed Sensor
Coolant Temperature (5V)
Coolant Temperature (GM/Vauxhall Simtec
Crash Sensor
MAP Analog
MAP Digital
Hall Effect Road Speed Sensor
Accelerator Pedal (Bosch Diesel)

Bus Diagnosis

CAN Bus Data View
CAN Bus Signal Integrity
CAN Bus LH Long Capture
LIN Bus

Engine

Diesel Glow Plugs
Electronic Fuel Pump
Carbon Canister Solenoid Valve
ERG Recirculation Solenoid Valve
Stepper Motor Example 1
Stepper Motor Example 2
Idle Speed Control Valve (Rotary)
Idle Speed Control Valve (Electromagmetic)
Throttle Servomotor (Idling)
Throttle Servomotor (Accelerating)
Bosch CDi3 Quantity Control Valve
Bosch CDi3 Pressure Regulator Valve
Variable-Speed Cooling Fan On
Variable-Speed Cooling Fan Off
Variable Camshaft Valve Timing

Startup & Charge

Charging Circuits Current/Voltage
Charging Circuits Current/Voltage Starting 24V
Charging Circuits Current/Voltage Idling 24V
Charging Circuits Alternator AC Ripple/Diode Diagnosis
Relative Compression Petrol
Relative Compression Diesel
Starting Voltage Drop

Voltage Range

10mV to 5V/div @ x 1 probe
100mV to 50V/div @ x 10 probe
10V to 5000V/div @ x 1000 probe
100V to 50000V/div @ x 10000 probe
200mV to 100V/div @ 20:1

Current Range

100mA to50.0A/div @ CC65(20A)
1000mA to500.0A/div @ CC65(65A)
1A to100.0A/div @ CC650(60A)
1A to200.0A/div @CC1100(100A)
10A to2000.0A/div @CC1100(1100A)

LA COMPRA INCLUYE

- 1 Osciloscopio Hantek 1008C
- 1 Cable USB
- 8 sondas tipo caiman con conector bnc
- 1 Sonda capacitiva para la ignición (secundario de la bobina)
- 1 Cd de instalación incluye manual en Inglés'.